Preamble<Preamble>
RepCap Settings
# Range: Nr1 .. Nr400
rc = driver.prach.modulation.preamble.repcap_preamble_get()
driver.prach.modulation.preamble.repcap_preamble_set(repcap.Preamble.Nr1)
SCPI Commands :
READ:LTE:MEASurement<Instance>:PRACh:MODulation:PREamble<Number>
FETCh:LTE:MEASurement<Instance>:PRACh:MODulation:PREamble<Number>
- class PreambleCls[source]
Preamble commands group definition. 2 total commands, 0 Subgroups, 2 group commands Repeated Capability: Preamble, default value after init: Preamble.Nr1
- class ResultData[source]
Response structure. Fields:
1 Reliability: int: decimal ‘Reliability indicator’
2 Preamble_Rel: int: decimal Reliability indicator for the preamble.
3 Evm_Rms_Low: float: float EVM RMS value, low EVM window position. Unit: %
4 Evm_Rms_High: float: float EVM RMS value, high EVM window position. Unit: %
5 Evm_Peak_Low: float: float EVM peak value, low EVM window position. Unit: %
6 Evm_Peak_High: float: float EVM peak value, high EVM window position. Unit: %
7 Mag_Error_Rms_Low: float: float Magnitude error RMS value, low EVM window position. Unit: %
8 Mag_Error_Rms_High: float: float Magnitude error RMS value, low EVM window position. Unit: %
9 Mag_Error_Peak_Low: float: float Magnitude error peak value, low EVM window position. Unit: %
10 Mag_Err_Peak_High: float: float Magnitude error peak value, high EVM window position. Unit: %
11 Ph_Error_Rms_Low: float: float Phase error RMS value, low EVM window position. Unit: deg
12 Ph_Error_Rms_High: float: float Phase error RMS value, high EVM window position. Unit: deg
13 Ph_Error_Peak_Low: float: float Phase error peak value, low EVM window position. Unit: deg
14 Ph_Error_Peak_High: float: float Phase error peak value, high EVM window position. Unit: deg
15 Frequency_Error: float: float Carrier frequency error. Unit: Hz
16 Timing_Error: float: float Transmit time error. Unit: Ts (basic LTE time unit)
17 Tx_Power: float: float UE RMS power. Unit: dBm
18 Peak_Power: float: float UE peak power. Unit: dBm
- fetch(preamble=Preamble.Default) ResultData[source]
FETCh:LTE:MEASurement<Instance>:PRACh:MODulation:PREamble<Number>
Snippet: value: ResultData = driver.prach.modulation.preamble.fetch(preamble = repcap.Preamble.Default)
Return the single value results of the ‘EVM vs Preamble’ and ‘Power vs Preamble’ views, for a selected preamble. See also ‘View EVM vs Preamble, Power vs Preamble’.
- param preamble:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Preamble’)
- return:
structure: for return value, see the help for ResultData structure arguments.
- read(preamble=Preamble.Default) ResultData[source]
READ:LTE:MEASurement<Instance>:PRACh:MODulation:PREamble<Number>
Snippet: value: ResultData = driver.prach.modulation.preamble.read(preamble = repcap.Preamble.Default)
Return the single value results of the ‘EVM vs Preamble’ and ‘Power vs Preamble’ views, for a selected preamble. See also ‘View EVM vs Preamble, Power vs Preamble’.
- param preamble:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Preamble’)
- return:
structure: for return value, see the help for ResultData structure arguments.
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.prach.modulation.preamble.clone()