Current

SCPI Commands :

FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
class CurrentCls[source]

Current commands group definition. 2 total commands, 0 Subgroups, 2 group commands

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability indicator’

  • Seg_Reliability: int: decimal Reliability indicator for the segment

  • Statist_Expired: int: decimal Reached statistical length in slots

  • Out_Of_Tolerance: int: decimal Percentage of measured subframes with failed limit check Unit: %

  • Utra_2_Neg: enums.ResultStatus2: float ACLR for the second UTRA channel with lower frequency Unit: dB

  • Utra_1_Neg: enums.ResultStatus2: float ACLR for the first UTRA channel with lower frequency Unit: dB

  • Eutra_Negativ: enums.ResultStatus2: float ACLR for the first E-UTRA channel below the carrier frequency Unit: dB

  • Eutra: enums.ResultStatus2: float Power in the allocated E-UTRA channel Unit: dBm

  • Eutra_Positiv: enums.ResultStatus2: float ACLR for the first E-UTRA channel above the carrier frequency Unit: dB

  • Utra_1_Pos: enums.ResultStatus2: float ACLR for the first UTRA channel with higher frequency Unit: dB

  • Utra_2_Pos: enums.ResultStatus2: float ACLR for the second UTRA channel with higher frequency Unit: dB

class FetchStruct[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability indicator’

  • Seg_Reliability: int: decimal Reliability indicator for the segment

  • Statist_Expired: int: decimal Reached statistical length in slots

  • Out_Of_Tolerance: int: decimal Percentage of measured subframes with failed limit check Unit: %

  • Utra_2_Neg: float: float ACLR for the second UTRA channel with lower frequency Unit: dB

  • Utra_1_Neg: float: float ACLR for the first UTRA channel with lower frequency Unit: dB

  • Eutra_Negativ: float: float ACLR for the first E-UTRA channel below the carrier frequency Unit: dB

  • Eutra: float: float Power in the allocated E-UTRA channel Unit: dBm

  • Eutra_Positiv: float: float ACLR for the first E-UTRA channel above the carrier frequency Unit: dB

  • Utra_1_Pos: float: float ACLR for the first UTRA channel with higher frequency Unit: dB

  • Utra_2_Pos: float: float ACLR for the second UTRA channel with higher frequency Unit: dB

calculate(segment=Segment.Default) CalculateStruct[source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
value: CalculateStruct = driver.multiEval.listPy.segment.aclr.current.calculate(segment = repcap.Segment.Default)

Return ACLR single value results for segment <no> in list mode. The values described below are returned by FETCh commands. The first four values (reliability to out-of-tolerance result) are also returned by CALCulate commands. The remaining values returned by CALCulate commands are limit check results, one value for each result listed below.

param segment:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)

return:

structure: for return value, see the help for CalculateStruct structure arguments.

fetch(segment=Segment.Default) FetchStruct[source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:CURRent
value: FetchStruct = driver.multiEval.listPy.segment.aclr.current.fetch(segment = repcap.Segment.Default)

Return ACLR single value results for segment <no> in list mode. The values described below are returned by FETCh commands. The first four values (reliability to out-of-tolerance result) are also returned by CALCulate commands. The remaining values returned by CALCulate commands are limit check results, one value for each result listed below.

param segment:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)

return:

structure: for return value, see the help for FetchStruct structure arguments.