Average
SCPI Commands :
FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:AVERage
CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:AVERage
- class AverageCls[source]
Average commands group definition. 2 total commands, 0 Subgroups, 2 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Seg_Reliability: int: decimal Reliability indicator for the segment
Statist_Expired: int: decimal Reached statistical length in slots
Out_Of_Tolerance: int: decimal Percentage of measured subframes with failed limit check Unit: %
Utra_2_Neg: enums.ResultStatus2: float ACLR for the second UTRA channel with lower frequency Unit: dB
Utra_1_Neg: enums.ResultStatus2: float ACLR for the first UTRA channel with lower frequency Unit: dB
Eutra_Negativ: enums.ResultStatus2: float ACLR for the first E-UTRA channel below the carrier frequency Unit: dB
Eutra: enums.ResultStatus2: float Power in the allocated E-UTRA channel Unit: dBm
Eutra_Positiv: enums.ResultStatus2: float ACLR for the first E-UTRA channel above the carrier frequency Unit: dB
Utra_1_Pos: enums.ResultStatus2: float ACLR for the first UTRA channel with higher frequency Unit: dB
Utra_2_Pos: enums.ResultStatus2: float ACLR for the second UTRA channel with higher frequency Unit: dB
- class FetchStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Seg_Reliability: int: decimal Reliability indicator for the segment
Statist_Expired: int: decimal Reached statistical length in slots
Out_Of_Tolerance: int: decimal Percentage of measured subframes with failed limit check Unit: %
Utra_2_Neg: float: float ACLR for the second UTRA channel with lower frequency Unit: dB
Utra_1_Neg: float: float ACLR for the first UTRA channel with lower frequency Unit: dB
Eutra_Negativ: float: float ACLR for the first E-UTRA channel below the carrier frequency Unit: dB
Eutra: float: float Power in the allocated E-UTRA channel Unit: dBm
Eutra_Positiv: float: float ACLR for the first E-UTRA channel above the carrier frequency Unit: dB
Utra_1_Pos: float: float ACLR for the first UTRA channel with higher frequency Unit: dB
Utra_2_Pos: float: float ACLR for the second UTRA channel with higher frequency Unit: dB
- calculate(segment=Segment.Default) CalculateStruct [source]
# SCPI: CALCulate:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:AVERage value: CalculateStruct = driver.multiEval.listPy.segment.aclr.average.calculate(segment = repcap.Segment.Default)
Return ACLR single value results for segment <no> in list mode. The values described below are returned by FETCh commands. The first four values (reliability to out-of-tolerance result) are also returned by CALCulate commands. The remaining values returned by CALCulate commands are limit check results, one value for each result listed below.
- param segment:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch(segment=Segment.Default) FetchStruct [source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:ACLR:AVERage value: FetchStruct = driver.multiEval.listPy.segment.aclr.average.fetch(segment = repcap.Segment.Default)
Return ACLR single value results for segment <no> in list mode. The values described below are returned by FETCh commands. The first four values (reliability to out-of-tolerance result) are also returned by CALCulate commands. The remaining values returned by CALCulate commands are limit check results, one value for each result listed below.
- param segment:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)
- return:
structure: for return value, see the help for FetchStruct structure arguments.