from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal import Conversions
from ..... import repcap
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]
class FrequencyCls:
"""Frequency commands group definition. 1 total commands, 0 Subgroups, 1 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("frequency", core, parent)
[docs]
def set(self, analyzer_freq: float, carrierComponent=repcap.CarrierComponent.Default) -> None:
"""SCPI: CONFigure:LTE:MEASurement<Instance>:RFSettings:CC<Nr>:FREQuency \n
Snippet: driver.configure.rfSettings.cc.frequency.set(analyzer_freq = 1.0, carrierComponent = repcap.CarrierComponent.Default) \n
Selects the center frequency of component carrier CC<no>. Without carrier aggregation, you can omit <no>. Using the unit
CH, the frequency can be set via the channel number. The allowed channel number range depends on the operating band, see
'Frequency bands'.
INTRO_CMD_HELP: For the combined signal path scenario, use: \n
- CONFigure:LTE:SIGN<i>:RFSettings[:PCC]:CHANnel:UL
- CONFigure:LTE:SIGN<i>:RFSettings:SCC<c>:CHANnel:UL
For the supported frequency range, see 'Frequency ranges'. \n
:param analyzer_freq: numeric Unit: Hz
:param carrierComponent: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Cc')
"""
param = Conversions.decimal_value_to_str(analyzer_freq)
carrierComponent_cmd_val = self._cmd_group.get_repcap_cmd_value(carrierComponent, repcap.CarrierComponent)
self._core.io.write(f'CONFigure:LTE:MEASurement<Instance>:RFSettings:CC{carrierComponent_cmd_val}:FREQuency {param}')
[docs]
def get(self, carrierComponent=repcap.CarrierComponent.Default) -> float:
"""SCPI: CONFigure:LTE:MEASurement<Instance>:RFSettings:CC<Nr>:FREQuency \n
Snippet: value: float = driver.configure.rfSettings.cc.frequency.get(carrierComponent = repcap.CarrierComponent.Default) \n
Selects the center frequency of component carrier CC<no>. Without carrier aggregation, you can omit <no>. Using the unit
CH, the frequency can be set via the channel number. The allowed channel number range depends on the operating band, see
'Frequency bands'.
INTRO_CMD_HELP: For the combined signal path scenario, use: \n
- CONFigure:LTE:SIGN<i>:RFSettings[:PCC]:CHANnel:UL
- CONFigure:LTE:SIGN<i>:RFSettings:SCC<c>:CHANnel:UL
For the supported frequency range, see 'Frequency ranges'. \n
:param carrierComponent: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Cc')
:return: analyzer_freq: numeric Unit: Hz"""
carrierComponent_cmd_val = self._cmd_group.get_repcap_cmd_value(carrierComponent, repcap.CarrierComponent)
response = self._core.io.query_str(f'CONFigure:LTE:MEASurement<Instance>:RFSettings:CC{carrierComponent_cmd_val}:FREQuency?')
return Conversions.str_to_float(response)