Srs
SCPI Commands :
TRIGger:LTE:MEASurement<Instance>:SRS:SOURce
TRIGger:LTE:MEASurement<Instance>:SRS:THReshold
TRIGger:LTE:MEASurement<Instance>:SRS:SLOPe
TRIGger:LTE:MEASurement<Instance>:SRS:TOUT
TRIGger:LTE:MEASurement<Instance>:SRS:MGAP
- class SrsCls[source]
Srs commands group definition. 6 total commands, 1 Subgroups, 5 group commands
- get_mgap() float [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:MGAP value: float = driver.trigger.srs.get_mgap()
Sets a minimum time during which the IF signal must be below the trigger threshold before the trigger is armed so that an IF power trigger event can be generated.
- return:
min_trig_gap: float Range: 0 s to 1E-3 s, Unit: s
- get_slope() SignalSlope [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:SLOPe value: enums.SignalSlope = driver.trigger.srs.get_slope()
Qualifies whether the trigger event is generated at the rising or at the falling edge of the trigger pulse (valid for external and power trigger sources) .
- return:
slope: REDGe | FEDGe REDGe: Rising edge FEDGe: Falling edge
- get_source() str [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:SOURce value: str = driver.trigger.srs.get_source()
Selects the source of the trigger events. Some values are always available. They are listed below. Depending on the installed options, additional values are available. You can query a list of all supported values via TRIGger:… :CATalog:SOURce?.
- return:
source: string ‘IF Power’: Power trigger (received RF power)
- get_threshold() float [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:THReshold value: float or bool = driver.trigger.srs.get_threshold()
Defines the trigger threshold for power trigger sources.
- return:
trig_threshold: (float or boolean) numeric Range: -50 dB to 0 dB, Unit: dB (full scale, i.e. relative to reference level minus external attenuation)
- get_timeout() float [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:TOUT value: float or bool = driver.trigger.srs.get_timeout()
Selects the maximum time that the measurement waits for a trigger event before it stops in remote control mode or indicates a trigger timeout in manual operation mode. This setting has no influence on ‘Free Run’ measurements.
- return:
trigger_timeout: (float or boolean) numeric | ON | OFF Range: 0.01 s to 167772.15 s, Unit: s ON | OFF enables or disables the timeout.
- set_mgap(min_trig_gap: float) None [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:MGAP driver.trigger.srs.set_mgap(min_trig_gap = 1.0)
Sets a minimum time during which the IF signal must be below the trigger threshold before the trigger is armed so that an IF power trigger event can be generated.
- param min_trig_gap:
float Range: 0 s to 1E-3 s, Unit: s
- set_slope(slope: SignalSlope) None [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:SLOPe driver.trigger.srs.set_slope(slope = enums.SignalSlope.FEDGe)
Qualifies whether the trigger event is generated at the rising or at the falling edge of the trigger pulse (valid for external and power trigger sources) .
- param slope:
REDGe | FEDGe REDGe: Rising edge FEDGe: Falling edge
- set_source(source: str) None [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:SOURce driver.trigger.srs.set_source(source = 'abc')
Selects the source of the trigger events. Some values are always available. They are listed below. Depending on the installed options, additional values are available. You can query a list of all supported values via TRIGger:… :CATalog:SOURce?.
- param source:
string ‘IF Power’: Power trigger (received RF power)
- set_threshold(trig_threshold: float) None [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:THReshold driver.trigger.srs.set_threshold(trig_threshold = 1.0)
Defines the trigger threshold for power trigger sources.
- param trig_threshold:
(float or boolean) numeric Range: -50 dB to 0 dB, Unit: dB (full scale, i.e. relative to reference level minus external attenuation)
- set_timeout(trigger_timeout: float) None [source]
# SCPI: TRIGger:LTE:MEASurement<Instance>:SRS:TOUT driver.trigger.srs.set_timeout(trigger_timeout = 1.0)
Selects the maximum time that the measurement waits for a trigger event before it stops in remote control mode or indicates a trigger timeout in manual operation mode. This setting has no influence on ‘Free Run’ measurements.
- param trigger_timeout:
(float or boolean) numeric | ON | OFF Range: 0.01 s to 167772.15 s, Unit: s ON | OFF enables or disables the timeout.
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.trigger.srs.clone()
Subgroups