Peak

SCPI Command :

FETCh:LTE:MEASurement<Instance>:MEValuation:AMARker<No>:EVMagnitude:PEAK
class PeakCls[source]

Peak commands group definition. 1 total commands, 0 Subgroups, 1 group commands

fetch(xvalue: int, trace_select: TraceSelect, absMarker=AbsMarker.Default) float[source]
# SCPI: FETCh:LTE:MEASurement<Instance>:MEValuation:AMARker<No>:EVMagnitude:PEAK
value: float = driver.multiEval.amarker.evMagnitude.peak.fetch(xvalue = 1, trace_select = enums.TraceSelect.AVERage, absMarker = repcap.AbsMarker.Default)

Uses the markers 1 and 2 with absolute values on the bar graphs: EVM RMS, EVM peak, magnitude error and phase error vs SC-FDMA symbol.

Use RsCmwLteMeas.reliability.last_value to read the updated reliability indicator.

param xvalue:

(integer or boolean) integer Absolute X value of the marker position There are two X values per SC-FDMA symbol on the X axis (symbol 0 low, symbol 0 high, …, symbol 6 low, symbol 6 high) . Range: 0 to 13

param trace_select:

CURRent | AVERage | MAXimum

param absMarker:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Amarker’)

return:

yvalue: float Absolute Y value of the marker position