Tmode
SCPI Commands :
CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:SCOunt
CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:ENPower
CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:RLEVel
- class TmodeCls[source]
Tmode commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- get_envelope_power() List[float] [source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:ENPower value: List[float] = driver.configure.multiEval.tmode.get_envelope_power()
Defines the expected nominal power values for all entries of the ‘TPC Mode’ list. For definition of the corresponding subframe count values, see method RsCmwLteMeas.Configure.MultiEval.Tmode.scount.
- return:
exp_nom_pow: numeric Comma-separated list of 16 values, for list entry number 0 to 15 The range of the expected nominal power can be calculated as follows: Range (Expected Nominal Power) = Range (Input Power) + External Attenuation - User Margin The input power range is stated in the data sheet. Unit: dBm
- get_rlevel() List[float] [source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:RLEVel value: List[float] = driver.configure.multiEval.tmode.get_rlevel()
Queries the reference level for all entries of the ‘TPC Mode’ list. The reference level is calculated from the expected nominal power of each entry and the user margin.
- return:
reference_level: float Comma-separated list of 16 values, for list entry number 0 to 15 The range of the reference levels can be calculated as follows: Range (Reference Level) = Range (Input Power) + External Attenuation The input power range is stated in the data sheet. Unit: dBm
- get_scount() List[int] [source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:SCOunt value: List[int] = driver.configure.multiEval.tmode.get_scount()
Defines the subframe counts for all entries of the ‘TPC Mode’ list. For definition of the corresponding expected nominal power values, see method RsCmwLteMeas.Configure.MultiEval.Tmode.envelopePower.
- return:
sub_frame_count: decimal Comma-separated list of 16 values, for list entry number 0 to 15 Range: 1 to 320
- set_envelope_power(exp_nom_pow: List[float]) None [source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:ENPower driver.configure.multiEval.tmode.set_envelope_power(exp_nom_pow = [1.1, 2.2, 3.3])
Defines the expected nominal power values for all entries of the ‘TPC Mode’ list. For definition of the corresponding subframe count values, see method RsCmwLteMeas.Configure.MultiEval.Tmode.scount.
- param exp_nom_pow:
numeric Comma-separated list of 16 values, for list entry number 0 to 15 The range of the expected nominal power can be calculated as follows: Range (Expected Nominal Power) = Range (Input Power) + External Attenuation - User Margin The input power range is stated in the data sheet. Unit: dBm
- set_scount(sub_frame_count: List[int]) None [source]
# SCPI: CONFigure:LTE:MEASurement<Instance>:MEValuation:TMODe:SCOunt driver.configure.multiEval.tmode.set_scount(sub_frame_count = [1, 2, 3])
Defines the subframe counts for all entries of the ‘TPC Mode’ list. For definition of the corresponding expected nominal power values, see method RsCmwLteMeas.Configure.MultiEval.Tmode.envelopePower.
- param sub_frame_count:
decimal Comma-separated list of 16 values, for list entry number 0 to 15 Range: 1 to 320